| Enclosed | 2 Contactor Bypass | 3 Contactor Bypass | ||
| Hp Ratings | 208VAC, 3PH, 60Hz | 3 - 125Hp | 3 - 125Hp | 3 - 125Hp |
| 460VAC, 3PH, 60Hz | 3 - 300Hp | 3 - 300Hp | 3 - 300Hp | |
| Environment | Ambient Temperature | -10°C to 40°C | -10°C to 40°C | -10°C to 40°C |
| Humidity (RH, non-condensing) | 5% to 95% | 5% to 95% | 5% to 95% RH | |
| Elevation | 0 to 3,300 ft | 0 to 3,300 ft | 0 to 3,300 ft | |
| Enclosure Type, Style | UL Type 1, Wall-Mount | Std (3-30Hp @ 208V) (3-75Hp @ 460V) | Std (3-30Hp @ 208V) (3-75Hp @ 460V) | Std (3-30Hp @ 208V) (3-75Hp @ 460V) |
| NEMA 12 Ventilated, Wall-Mount | Opt (3-30Hp @ 208V) (3- 75Hp @ 460V) | Opt (3-30Hp @ 208V) (3-75Hp @ 460V) | Opt (3-30Hp @ 208V) (3-75Hp @ 460V) | |
| NEMA 12 Ventilated, Floor-Mount | Std (40-125Hp @ 208V) (100-300Hp @ 460V)/td> | Std (40-125Hp @ 208V) (100-300Hp @ 460V)/td> | Std (40-125Hp @ 208V) (100-300Hp @ 460V) | |
| Codes & Standards | UL & cUL | Std | Std | Std |
| Power Circuit Features | Non-Fused Disconnect w/ Separate Mounted Fuses (panel short circuit current rating = 50kA) | Std | Std | Std |
| Mag-Break Circuit Breaker (MCP) (panel short circuit current rating = 65kA) | Opt | Opt | Opt | |
| DC Link Reactor | Std (>100Hp) | Std (>100Hp) | Std (>100Hp) | |
| 3% AC Line Reactor Std | (<75Hp), Opt (>100Hp) | Std (<75Hp), Opt (>100Hp) | Std (<75Hp), Opt (>100Hp) | |
| 5% AC Line Reactor | Opt | Opt | Opt | |
| Drive Output Contactor | - | Std | Std | |
| Bypass Contactor | - | Std | Std | |
| Class 20 Overload Relay | - | Std | Std | |
| Isolation Contactor | - | - | Std | |
| Control Circuit Features | Power On Light | Std | Std | Std |
| Enable Light | Std | Std | Std | |
| Bypass Light | - | Std | Std | |
| Motor Overload Light | - | Std | Std | |
| Normal Light | - | - | Std | |
| Drive Run & Fault Lights | - | Opt | Opt | |
| Local-Remote Switch | Std | - | - | |
| Hand-Off-Auto Switch | - | Std | Std | |
| Drive-Off-Bypass Switch | - | Std | Std | |
| Test-Isolate-Normal Switch | - | - | Std | |
| Speed Potentiometer | Opt | Opt | Opt | |
| Control Power Transformer | Std | Std | Std | |
| Automatic Bypass | - | Opt | Opt | |
| Smoke Purge Relay | Opt | Opt | Opt | |
| Elapsed Time Meter | Opt | Opt | Opt | |
| Customer I/O Terminal Board | Std | Std | Std | |
| Quantity 2 Enable Inputs | Std | Std | Std | |
| Remote Bypass Input | - | Std | Std | |
| Loss of 4-20mA Speed Ref to Preset Speed | Opt | Opt | Opt | |
| Bypass Output (N.O.) | - | Std | Std | |
| Drive Run Output (N.O.) | Std | Std | Std | |
| Drive Fault Output (1N.O.-1N.C.) | Std | Std | Std | |
| 4-20mA Output & Relay Output (1N.O.-1N.C.) | Opt | Opt | Opt | |
| Drive Communication Options | Modbus RTU | Std | Std | Std |
| LONWORKS® | Opt | Opt | Opt | |
| APOGEE® FLN | Opt | Opt | Opt | |
| Metasys® N2 | Opt | Opt | Opt | |
| Ethernet TCP/IP | Opt | Opt | Opt |